Pensafe Recalls

2/24/2012

PENSAFE/CAPITAL SAFETY

3730 Anchorage Connector with a manufacturing code 07B

Capital Safety parts affected by the PenSafe recall, reissued February 7, 2012, include the following: AN112A anchorage connector and Vacuum Anchor models; 2200104, 2200106, 2200047, 2200046, 2200045, 2200037, 2200036.

Details

2/7/2012

PENSAFE

3730 Anchorage Connector with a manufacturing code 07B

Connectors may be subject to embrittlement that may cause the threads of the stem to fracture. PenSafe has issued a 2nd Release of its Recall Notice, dated February 7, 2012, reminding its customers of the ongoing recall.

Details

10/26/2011

PENSAFE

3730 Anchorage Connector

Connectors may be subject to embrittlement that may cause the threads of the stem to fracture.

9/30/2010

PENSAFE

3730 Anchorage Connectors with the 07 B year and heat code

A heat treatment deficiency resulted in a potential embrittlement on anchorage connectors. This embrittlement may cause the threads on the stem to fracture prematurely from stress created by the torque of the nut during installation.